Please activate JavaScript!
Please install Adobe Flash Player, click here for download

implants - international magazine of oral implantology No.1, 2018

expert article _ simplified apposition technique Fig. 4a Fig. 4b _consigli di lettura 1. Roccuzzo M, Gaudioso L, Bunino M, Dalmasso P. Long term stability of soft tissues following alve- olar ridge preservation: 10 year results of a pro- spective study around nonsubmerged implants. Int J Periodontics Restorative Dent 2014;34:795-804. 2. Milani S, Dal Pozzo L, Rasperini G, Sforza C, Della- via C. Deproteinized bovine bone remodeling pat- tern in alveolar socket: a clinical immunoistological evaluation. Clin Oral Implants Res 00, 2014, 1-8. 3. Lindhe J, Cecchinato D, Donati M, Tomasi C, Liljenberg B. Ridge preservation with the use of de- proteinized bovine bone mineral. Clin Oral Implants Res 25, 2014, 786-790. 4. Borgia V, Alfonsi F, Iezzi G, Piattelli A, Covani U, Ba- rone A. Valutazione istologica della preservazione di cresta alveolare. Implant Tribune Italian Edition – Maggio 2013. 5. Cardaropoli D, Tamagnone L, Roffredo A, Gaveglio L. Evaluation of dental implants placed in preser- ved and non preserved postextraction ridges: a 12-month postloading study. Int J Periodontics Restorative Dent 2015;35:676-684. 6. Istvan A. Urban, Jaime L. Lozada, Sasha A. Jova- novic, Katalin Nagy. Horizontal Guided Bone Re- generation in the Posterior Maxilla Using Recom- binant Human Platelet-Derived Growth Factor: A case Report. Int J Periodontics Restorative Dent 2013;33:421-425. Istvan A. Urban, Heiner Nagursky, Jaime L. Lozada, Katalin Nagy. Horizontal Ridge Augmentation with a Collagen Membran and a Combination of Particulated Autogenous Bone and Anorganic Bovine Bone-Deri- ved Mineral: A Prospective Case Series in 25 Patients. Int J Periodontics Restorative Dent 2013;33:299-307. 7. 8. Subperiosteal Minimally Invasive Aesthetic Ridge Augmentation Technique (SMART): A New Standard for Bone Reconstruction of the Jaws. Int J Periodon- tics Restorative Dent 2017 Mar/Apr;37(2):165-173. Fig. 5 Fig. 4a_Elemento 36 mesio inclinato, deficit orizzontale in zona 35 risolto con tecnica S.A.T. Fig. 4b_Controllo a 12 mesi dal carico. Fig. 5_Elemento di ponte 35 perso e deficit in zona 36, controllo a 16 mesi dal carico. 34 1_2018 dolore è molto limitato e gestibile con poche dosi di antidolorifico per via orale, oltre la tera- pia antibiotica con Amoxicillina 875 mg. e Acido Clavulanico 125 mg. ogni 12 ore per sei giorni. Il primo caso risale al gennaio 2011 ed abbiamo quindi un controllo a più di 4 anni dal posizio- namento implantare (Fig. 7). La stabilità dei tes- suti duri e molli è risultata buona, non avendo perso alcun impianto e soprattutto non avendo casi di perimucosite-perimplantite.

Sito