around the retention cham- ber and the air channels were thoroughly cleaned (Fig 46). The valve covers were opened over a receptacle of water to avoid losing the components. The valves were cleaned and the diaphragms replaced. Patients were in- structed to clean their den- tures and the valves on a daily basis. Patients who had manual dexterity were given the service key, together with spare diaphragms and were instructed to perform routine maintenance in between the biannual visits (Figs 47-51). Discussion Ultra Suction system appears to increase considerably the re- tention of complete dentures in both clinical observations and statistical findings. Their reten- tive capacity is superior to that of conventional dentures. The decrease in the rate of applied negative force by 10mmHg per 15 seconds, attributed to the design of the diaphragms, sug- gests that we may have a more tissue friendly denture than we first thought. It is well known that the supporting tissue is subject to -80mmHg under con- ventional maxillary dentures, which caused an increase in epithelial width in the palate and attached gingival, and a de- crease in the epithelial width in the alveolar mucosa4 in most, if not all, complete denture wear- ers. The response is directly re- lated to the functional demands of the tissue. In view of this documented evidence, it would be responsible to conclude that Ultra Suction’s negative force is less invasive that that of con- ventional dentures. DT 17Lab TribuneApril 16-22, 2012United Kingdom Edition For more information, contact BioHorizons Customer Care: +44 (0)1344 752560 or visit us online at www.biohorizons.com Laser-Lok 3.0 is the first 3mm implant that incorporates Laser-Lok technology to create a biologic seal and maintain crestal bone on the implant collar1 . Designed specifically for limited spaces in the aesthetic zone, the Laser-Lok 3.0 comes with a broad array of prosthetic options making it the perfect choice for high profile cases. SPMP10109 REV D SEP 2010 1. Radiographic Analysis of Crestal Bone Levels on Laser-Lok Collar Dental Implants. CA Shapoff, B Lahey, PA Wasserlauf, DM Kim, IJPRD, Vol 30, No 2, 2010. 2. Implant strength & fatigue testing done in accordance with ISO standard 14801. 3. Initial clinical efficacy of 3-mm implants immediately placed into function in conditions of limited spacing. Reddy MS, O’Neal SJ, Haigh S, Aponte-Wesson R, Geurs NC. Int J Oral Maxillofac Implants. 2008 Mar-Apr;23(2):281-288. 4. Human Histologic Evidence of a Connective Tissue Attachment to a Dental Implant. M Nevins, ML Nevins, M Camelo, JL Boyesen, DM Kim. International Journal of Periodontics & Restorative Dentistry. Vol. 28, No. 2, 2008. • Two-piece 3mm design offers restorative flexibility in narrow spaces • Implant design is more than 20% stronger than competitor implant2 • 3mm threadform shown to be effective when immediately loaded3 • Laser-Lok microchannels create a physical connective tissue attachment (unlike Sharpey fibers) 4 Treat small spaces with confidence Introducing the Laser-Lok® 3.0 implant Human histology shows the apical extent of the junctional epithelium below which there is a supracrestal connective tissue attachment to the laser microchannel surface2 . Radiograph shows proper implant spacing in limited site. Laser-Lok 3.0 placed in aesthetic zone. Image courtesy of Michael Reddy, DDS Image courtesy of Cary Shapoff, DDS Treat small spaces with confidence spaces with confidence spaces with Introducing the Laser-LokIntroducing the Laser-Lok® 3.0 implant3.0 implant Bio Horizons_treat small.indd 1 01/03/2011 16:33 References 1. Badra SH, Radi I, Aboulela Aet al. The effect of Ultra Suction system on re- tentionof mandibular complete denture. EDJ Vol.56 Jan 2010. 2. Rahn AO, Heartwell CM. Text book of complete denture [5th ed.] BC Decker Inc. Hamilton London. 3. Zarb GA, Bolender CL, Carlsson G. Boucher’s Prosthodontic Treatment for Edentulous Patients. [11th ed.] St. Louis C.V. Mosby, 1997: 460-468. 4. Grossman ES, Forbes ME. Studies re- lated to reaction of supporting soft tissue to denture wear: the histological response of vervet monkey oral epithelium to a -80mmHg vacuum. J Oral Rehabbil. 1990 Nov;17(6): 587-97. 5. Yi – Cheong Jae. Ultra Suction Denture, Journal of Korean Academy of Dental Technology Vol.29 No2. About the author For more information contact the UK distributors: Abacus Dental, 7 Oxford Place, Brad- ford, West Yorkshire, BD3 0EF Email: chrisb@abacus-dental.com Fig 50 Fig 51 Fig 52