Please activate JavaScript!
Please install Adobe Flash Player, click here for download

Dental Tribune U.S. Edition

raise the proximal contact up, which makes the proximal contact shy at the delivery appointment. This also creates an unstable situ- ation because that tooth can now drift either mesially or distally, creating possible occlusal interferences. The only way to have predictable, adjust- ment-free delivery appointments is to correctly equilibrate the accurately mounted working casts. This will take a trained technician approximately five to six minutes per case. This technique should be used for all restorations whether Emax, Empress, LAVA, Cristobal+, Belle- Glass, Implants, PFM, etc. It can also be used on all partial denture cases. Anything involving natural teeth, from full-arch impressions or double bite trays — this technique should be employed, always! An example of model equilibration for a #30 Centric equilibration 1) Opposing model and working models are both poured in liquid/pow- der ratio measured die stone. (Cru- cial!) 2) After mounting accurately, verify the mounting. Bite should not be taken with base plate wax but with a polyvi- nyl bite material that can be trimmed to allow only cusp tip show through. Use double-sided, Exacta-film red/ black of 19-micron thickness, use black for centric, tap models together. Notice not all teeth are in contact. 3) Initial incline contacts should be removed. Do not ever remove cusp tips. Remove only inclines, as would be done for intraoral equilibration. Adjustment-free appointments are actually possible and can be routine. Delivering veneers, inlays, onlays, crowns, bridges and partial dentures with very little or no proximal and occlusal adjustment can be common when a laboratory adheres to a strict protocol of die handling and die spac- ing, and has a firm understanding of cusp to fossa occlusion and anterior guidance. The laboratory must also possess a strong understanding of how to prop- erly equilibrate correctly mounted stone models and understand solid model verification. Basic cusp to fossa occlusion occurs when cusp inclines on posterior teeth do not touch other posterior inclines. Cusp tips must hit static stops in cen- tral fossa. In laboratory model equilibra- tion there is nothing more than the removal of all incline interferences and allowing cusp tips to occlude at 90-degree angles to opposing mar- ginal ridges and central fossa. Anterior guidance should allow complete free- dom from maximum intercuspation, immediately with lateral guidance on the canines. This will not activate the elevator muscles, therefore decreasing any chances of TMD. Equilibrating mounted casts is crucial to achieving adjustment-free delivery appointments. Less than 1 percent of technicians understand why we need to, much less, how to perform this task. Because of this, the following are common techniques used to try to achieve adjustment-free cementation appointments: • Placing metal foil under the work- ing die to create a space. If too much foil is used, the crown may be shy of occlusal contact. When that tooth does erupt into occlusion, it may work into an incline interference, creating an avoidance pattern for the mandible. • Pushing die up so crown appears out of occlusion on the model. After all, dentists do not want to adjust occlu- sion, so just leave it out of contact altogether. The flaw with both of these tech- niques is there is no way to gauge how much to leave the crown out of occlusion so it is correct in the mouth. These techniques can never be exactly correct, and they both create problems for proximal contacts because they 3a) A black dot stable holding con- tact should be found in the fossa of adjacent teeth; #31 and #29 in this example. 3b) There should be no con- tacts found on inclines, only on cusp tips and fossa. These hold- ing contacts are found on all teeth. You can now proceed to the ante- rior guidance equilibration process. Lateral equilibration 4) There should be no change in vertical dimension of the equilibrated models in centric because this rep- licates a “power clinch” of all teeth. (Periodontal ligaments are fully depressed.) 4a) With the red side of Exacta-film, move models laterally and remove all red marks except those on canines, without removing black holding con- tacts on posterior teeth. The goal is to have black dots on all posterior teeth and red marks on the anterior teeth. 4b) At Williams Dental Laboratory, we go one step further to absolutely ensure no posterior interferences. We know all healthy teeth intrude into their periodontal ligament and move laterally. In this example, imagine the canine will move laterally 56 to 75 microns in a clinching lateral force. 4c) We safely remove approximate- ly 5 degrees off of canine disclusion to further “shallow” the guidance to ensure no posterior interferences. Posterior interferences must then be rechecked. Remember: the key is that lateral equilibration will not change the vertical dimension, only shallow the disclusion, further ensuring no posterior interferences. Now, and not until now, are the models ready to be utilized as an accu- rate portrayal of the mouth. This system, along with the use of a solid proximal contact model and soft- tissue model, should be employed on all cases in the laboratory regardless of material choice. DT Laboratory communication Is it possible to achieve minimal- to no-adjustment bonding appointments? By Bob Clark, CDT, LVIM (Photo/Provided by Williams Dental Lab) About the author Bob Clark, CDT, LVIM, is the first and only lab technician in the world to receive mastership status with LVI. He is co-owner of Williams Dental Laboratory, a small family-operated, full- service lab located in Gilroy, Calif. He and his team have been working and training with LVI dentists for many years. Clark may be reached at (800) 713- 5390 or bob@williamsdentallab. com. Industry News DENTAL TRIBUNE | September 201122A sterilizable up to 135 degrees Cel- cius. Safe for you and your patient! Unique With its 17 increments, the power setting perfectly suits any individu- al clinical requirement. The gentle start for endo applications will be gradually enhanced for scaling and preparation applications and finally boosted for restorative treatments. Simultaneously, continuous feed- back control combines with intelli- gent Piezon No Pain technology to deliver a smooth sinus signal for gentle and pain-free treatment. Optimum instrument control and maximum visibility thanks to the LED’s circular light emission result in foremost efficiency in all applica- tions. The right formula for smooth tooth surfaces, maximum protec- tion of the gums and virtually pain- less treatment. DT For more information: EMS Corporation 11886 Greenville Ave., #120 Dallas, Texas 75243 Phone: (972) 690-8382 Fax: (972) 690-8981 info@ems-na.com www.ems-dent.com f DT page 21A